Lighting that follows daylight
The more sun comes in, the fewer lights are on. Without touching a switch.
First it checks that every data point arrives. Then it compares it with what is expected, classifies it and cross-checks the four dimensions: that is where the saving appears.
A saving calculated with incomplete data cannot be defended. That is why, before analysing, Metrics checks that every measuring point sends what it should. Each one has its own record: expected sampling, valid range, unit and type, and the facility services person who looks after that building.
Per measuring point and per day. 96 of 96 samples: 100 %.
Sensor with a flat battery, no coverage or disconnected. “No data since 03:15”.
The sensor has hung: an identical 21.0 °C for 9 hours.
CO₂ at 0 ppm or 85 °C in an office.
Meter replaced or reset: from 48,210 kWh to 120 kWh.
Low battery or weak signal, before it stops sending.
Flagged on the building's screen.
Alert to the building's facility services.
Escalates to the account manager.
Example thresholds, configurable per building.
With the data guaranteed, Metrics compares each sample with what is expected for that time, that day of the week, that outdoor weather and that occupancy. Each one falls into one of four states.
On a Tuesday at 11:00 the floor consumes what it does on any Tuesday with that weather. It feeds the baseline, the indicators and the reports.
On a Saturday with nobody in, the building consumes like a working day. Metrics flags it and looks for the cause: a badly programmed schedule, equipment left on or a change of use.
Demand exceeds the contracted power at 8:30, when all the HVAC starts up at once. It alerts you at that moment and calculates what it costs.
The HVAC starts at 5:00 and the first person arrives at 8:15, every day. Metrics quantifies the saving in € and kWh, proposes the action and measures the result afterwards.
“Expected” is not an average. For each building, Metrics builds a baseline adjusted for outdoor weather (degree-days), day of the week and real occupancy. That way, a hot day is not mistaken for an anomaly and the saving from an action is measured with method, not by eye.
One dimension on its own tells you what is happening. Two together tell you why. These are the combinations that give the most opportunities.
At what times energy is exported to the grid while the building buys energy at others. Action: shift loads to sunny hours (hot water, pre-cooling, vehicle charging).
Base load with the building empty: nights, weekends, floors with nobody on them. Action: adjust schedules and switch off by zone. Indicator: kWh per person.
CO₂ and people counting versus ventilation on a fixed schedule. Action: ventilate less when it is empty and more when it is full. Savings and better air.
Spaces at 21 °C in summer, heating and cooling at the same time in the same zone, setpoints nobody checks. Action: correct setpoints within the comfort range, with the data that proves it.
Real occupancy profile versus the solar curve. Action: decide on expanding the PV system or adding batteries with data, not assumptions.
kWh/m², kWh per person, % of hours in comfort, % self-consumption and CO₂ emissions. For ESG reports, BREEAM In-Use and the decarbonisation roadmap.
Illustrative office example, to explain the method. This is not client data.
On Tuesdays, group those people on floor 2, switch off floor 3 and use the surplus sun for other loads. See the building's performance; turn performance into savings.
That is exactly what Data Quality 100 % solves: if a data point is missing, the building's facility services get the alert.
The bill tells you how much, once a month. It doesn't tell you which system, at what time or whether anyone was there.
It depends on each building. As an external reference, not Alfred's own: Berkeley Lab estimates a 3% saving from monitoring and 9% from fault detection, and eu.bac puts the average payback of a building automation and control system (BACS) at under 3 years.
We'll show you your portfolio in Metrics with data from a pilot building.