Lighting that follows daylight
The more sun comes in, the fewer lights are on. Without touching a switch.
What the building generates, what it consumes, how it feels and how it is used, data point by data point. With or without a BMS, on top of what is already there and with no building work.

Measuring is not enough. A saving can only be defended if the data arrives complete, is understood and is cross-checked with everything else. We collect each data point from the systems the building already has (BMS, meters, inverter) or, if there are none, with wireless sensors and external sources. No building works.
What the building generates, what it consumes, how it feels and how it is used.
of monitored data. If one is missing, someone at the building knows.
We read what is there. What is not, we add without building works.
How much energy the building produces, how much it uses and how much it gives away to the grid. It is half the path to net-zero: it is not just about consuming less, but about consuming your own.
| Data | If the building has a BMS | If there is no BMS |
|---|---|---|
| Solar generationkW and kWh every 1–5 min | The BMS already reads the inverter (usually via Modbus). Metrics takes the data from the BMS. | The inverter manufacturer's cloud (Huawei, SMA, Fronius, SolarEdge…): connected with the client's permission, without installing anything. If there is no access, an energy meter at the inverter output. |
| Self-consumptionkWh and % of generation, every 15 min | Calculated: generation minus export. The BMS provides both figures if it integrates the meter at the grid connection point. | Metrics calculates it from the inverter data and a bidirectional meter in the main switchboard (clamps, without cutting the supply). |
| Grid exportkWh exported, every 15 min or daily | Bidirectional meter or power analyser in the main switchboard, read by the BMS. | The same bidirectional meter, in real time. For balance and billing, the distributor's load curve via Datadis, with the account holder's authorisation: it arrives a day or more late. |
| Storage% state of charge and kW of charge and discharge, every 1–5 min | The BMS reads the battery management system. | Almost always in the same cloud as the hybrid inverter. It is read the same way as generation. |
The bill is not enough: you need to know which system consumes, when and for what. That is usually where the biggest saving is, and the first thing whoever pays asks about.
| Data | If the building has a BMS | If there is no BMS |
|---|---|---|
| Main electricitykW, kWh, peak demand and reactive power, every 1–15 min | Power analyser in the main switchboard, read by the BMS. | Datadis: hourly or quarter-hourly curve from the distributor's meter, without installing anything (one day late). For real time, a split-core clamp analyser in the main switchboard: installed without cutting the power. |
| Consumption by end useHVAC, lighting, power, lifts, data centre, every 1–15 min | Meters in the sub-distribution boards, if the project included them. Many BMSs don't have them. | Wireless current clamps on each circuit of the sub-distribution boards. The heaviest circuits come first: HVAC, to begin with. |
| Heating and coolingThermal kWh, temperatures, setpoints, equipment status and gas, every 5–15 min | The BMS reads the central plant (chiller, boiler, heat pump) and the thermal energy meters. | Thermal energy meter with a clamp-on flow meter, without cutting pipes. On direct-expansion units, a gateway to the manufacturer's bus; with Alfred Clima, you can also act on the setpoints. Gas: pulse emitter or optical reader on the meter. |
| Cold and hot waterm³, flow and hot water energy, every 15–60 min | Meters with pulse output or M-Bus integrated into the BMS. | Pulse emitter or optical reader on the existing meter, by radio. Night-time flow gives leaks away. |
Saving has a limit: people's comfort. Measuring the environment space by space lets you save without anyone being cold, hot or breathing stale air, and prove it.
| Data | If the building has a BMS | If there is no BMS |
|---|---|---|
| Temperature and humidity°C and % relative humidity, every 5–10 min | Probes from the HVAC system. Watch out: they are usually in the return air or in one thermostat per zone, not where people are. | Battery-powered wireless sensor in each space, stuck to the wall. No cables and years of battery life. |
| CO₂ppm: how well the air is renewed, every 5–10 min | CO₂ probes in the return ducts of the air handling units, if there are any. | Wireless NDIR sensor in the space, the reliable technology for CO₂. It comes in the same device as temperature and humidity. |
| TVOC and PM2.5Volatile organic compounds and fine particles (µg/m³), every 10–15 min | A BMS rarely measures them. When it does, it is usually in the duct. | Multi-parameter air quality sensor. The particle sensor usually needs mains power: it goes next to a socket. |
| Light levellux, every 5–15 min | Light sensors from the lighting system (DALI, KNX), if the BMS integrates them. | Built into the same multi-parameter sensor. With Alfred Lights, lighting is dimmed according to daylight. |
It is the dimension almost nobody measures and the one that gives meaning to the other three. A building that consumes the same full as empty is overspending, and you only know by measuring use.
| Data | If the building has a BMS | If there is no BMS |
|---|---|---|
| PresenceOccupied or free, per room or per desk, on each change of state | Presence detectors from the lighting system (KNX, DALI), if the BMS exposes them. | Wireless presence sensor (infrared or radar) per room or desk. Anonymous: no cameras. |
| People countingPeople per space, floor and building, and capacity, every 1–15 min | A BMS rarely has it. | A counter at the doors that counts silhouettes without identifying anyone. With Alfred Control Aforos, occupancy in real time. |
| AccessEntries and exits, with their time | The existing access control, if it offers a connection (API) or exports logs. | Alfred Lock: connected locks and readers that log every opening. |
| BookingsBooked rooms, desks and shared areas | The client's booking tool, if it can be read. | Alfred Spaces. Cross-checked with presence, it uncovers booked rooms that stay empty. |
Every building has its own installation: one brand of BMS here, another there, standalone meters or radio sensors. The Alfred gateway reads each one in its own language and Metrics brings them together, with the same unit and the same period, so you can compare your whole portfolio.
Sample data.
On top of the BMS you already have
The Alfred gateway reads the BMS via BACnet, Modbus or KNX. Integration with each installation is checked during the technical visit.
Indicators with their change, electricity prices and the grid's footprint hour by hour, and a sentence that tells you what happened before you open a single table.
Part of the ecosystem
3GAmanager@yourcompany.comMetricsLog out| From the grid | 470 kWh |
| Solar | 16 kWh |
| Last 30 days | 15,212 kWh |
| Price paid | 111 €/MWh |
| Daily average | 107 €/MWh |
| Price | day-ahead market, excluding network charges |
| Grid, hour by hour | 64 g/kWh |
| Factor from the data sheet | no data |
| Cleanest hour | 10:00–11:00 · 34 g/kWh |
Its grid kWh came out 4% more expensive than the market average. The 4 most expensive hours of the day took 22% of the energy.
Whatever can be shifted (pre-cooling or pre-heating, hot water, EV charging) costs 100% less in the cheap slot than in the expensive one.
The grid was cleanest from 10:00 to 13:00 (35 g/kWh) and dirtiest from 19:00 to 22:00 (94).
Not even in the small hours does it drop below that load. At market prices that's around €1,120 a month in energy. It's worth checking what runs non-stop.
Electricity consumption was 17,369 kWh. Solar covered 4,2 % (731 kWh self-consumed), so only 17,360 kWh were paid for from the grid. That's 0.6 points less coverage than the previous month.
| Category | Amount | Sensors | Distribution |
|---|---|---|---|
| Solar generation | Generation 19,746 kWh | 2 / 2 | 21 % |
| Grid import | Import 50,712 kWh | 11 / 11 | 54 % |
| Grid export | Export 14,566 kWh | 11 / 11 | 16 % |
| Electricity consumption | Consumption 24,740 kWh | 21 / 24 | 27 % |
| Cold water | Consumption 180,51 m³ | 7 | 28 % |
| Water | Consumption 464,42 m³ | 21 / 24 | 72 % |
A turnkey service: platform, connectivity and maintenance in a single fee.
Are you a BREEAM, LEED or WELL assessor, an engineering firm or an energy consultancy? We work with specifiers: see Professionals.
The directive requires energy monitoring and control in phases, and in Spain part of it is already in the RITE (Spanish building thermal installations regulation). Check it in 10 seconds. Metrics provides that data, and the data BREEAM, WELL or LEED require.
Four dimensions: what the building generates (solar, self-consumption, export and batteries), what it consumes (electricity, heating and cooling, water), how it feels (temperature, humidity, CO₂, TVOC, particles and light) and how it is used (presence, people, access and bookings). All on the same screen and with the same history.
We count people without identifying them, without cameras, and process the data in aggregate.
Yes: the whole portfolio on one screen, compared by building and period, and each building in detail. With the digital twin, also on the building's floor plan.
We'll show you your portfolio in Metrics with data from a pilot building.