Lighting that follows daylight
The more sun comes in, the fewer lights are on. Without touching a switch.
Consumption, water, comfort and air measured continuously, with minimal infrastructure and without entering the homes or the commercial units. The monitoring evidence for Part 1 and the data for Part 2, throughout the three years of the certificate.
In a building in operation, monitoring requirements are usually left out for three reasons, and all three can be solved with minimal infrastructure.
The building has a main meter and little else. Without separating shared areas, commercial units and homes, there is no way to justify monitoring by end use.
Twelve readings a year from the energy supplier are not a data series. Part 2 asks for consumption data to be used to manage the building, not filed away.
Temperature, CO₂ and humidity in occupied spaces are not recorded. And when the owner hears “works” in an occupied building, the conversation stops.
With minimal infrastructure, we separate the consumption of shared areas, commercial units and homes from the meters already in place. Without fitting a meter in every home and without asking tenants for access.
A meter in every home and every commercial unit. You have to enter all of them, coordinate with each tenant and start works in an occupied building.
Metering on the shared meters and wireless sensors where the assessment requires them, with minimal infrastructure and with the building running.
V6 has two parts: Part 1 assesses the asset and Part 2 how it is managed. These are the requirements where continuous monitoring provides evidence.
| Requirements | Part | What is assessed | What Alfred Smart provides |
|---|---|---|---|
| Ene 15 · Ene 16 | 1 · Asset | Energy monitoring and monitoring of tenanted areas | Metering by use, unit or zone, with automatic readings and historical series. |
| Ene 11 | 1 · Asset | Installed controls | Reading of setpoints and temperatures. Control is handled by the BMS or the installed system. |
| Ag 01 | 1 · Asset | Water consumption monitoring | Reading of the water meters, with threshold alarms sent to the manager. |
| Syb 09 | 1 · Asset | Carbon dioxide sensors | CO₂ sensors in the main spaces, with their history. |
| Ene 23 | 2 · Management | Use of energy consumption data | The manager's dashboard with consumption by period and by zone, threshold alarms and reports. |
| Ag 13 | 2 · Management | Water consumption report | Water consumption reports by period and by zone. |
| Syb 14 | 2 · Management | Thermal comfort | Temperature and humidity measured continuously in occupied spaces. |
The four Metrics dimensions, in this standard: consumption and environment provide the evidence in the table. Generation and usage add management indicators, such as the self-consumption percentage or kWh per person. See the four dimensions →
Codes and titles from the BREEAM ES document “Alineación BREEAM® ES En Uso V6 y GRESB 2024” (alignment of BREEAM ES In-Use V6 with GRESB 2024). In V6 the assessment has two parts. The score and the validity of each piece of evidence, including derived consumption, are determined by the BREEAM assessor using the current manual and for each building. We give you the technical documentation so they can validate it.
What each part of the certificate asks for, and who makes sure the data keeps arriving until renewal.
LoRa sensors on the main meter and the sub-meters, and wireless temperature, CO₂ and humidity sensors in the spaces the assessment needs. This is the monitoring that scores in Part 1.
Energy, water and comfort reports by period and by zone, in PDF, Excel or CSV. And a read-only link so the BREEAM assessor can check the data without asking you for it.
The property manager doesn't have to chase data or technicians: we make sure the evidence is there at every review.
Monitoring stays active after the assessment. Part 2 follow-up and renewal start from real data, not a one-off snapshot.
Energy, water and comfort in one place, with reports exported by period and by zone. The manager sees it in Metrics.

Asset and property managers of buildings that are already running and cannot stop.
The asset keeps its BREEAM In-Use for the three years, and the same measured data is used to prepare for the EPBD and reporting ESG.
There is no need to ask each tenant to open their unit or home. And with each one's consumption separated, you can rebill it to tenants.
The consumption of each commercial unit and of the shared areas, separated without entering the shops.
Every metering point in the warehouse, read and sent to the cloud with minimal infrastructure.
The building's consumption and the comfort of the shared areas, without disturbing guests.
Start with a diagnosis with a specialist: which monitoring requirements it can cover, with what evidence and what would need to be installed.
There's no need to go in, and the infrastructure is minimal. We measure on the main meter and the existing sub-meters and separate uses by derived consumption. Comfort sensors are wireless and are installed with the building in operation.
Not for metering. If the building already has one, the Alfred platform gateway reads it and Metrics combines its data with the data from the meters and sensors, so systems aren't duplicated.
It keeps coming in throughout the three years of the certificate. It serves the management assessed in Part 2 and helps you prepare the renewal with measured data.
The BREEAM assessor decides, using the current manual and for each building. We tell you which requirements the measured data contributes to and give you the evidence so they can validate it.
Yes. Continuous energy monitoring is what the directive requires of many non-residential buildings. In Spain, for now, only automation for buildings over 290 kW is in force, through the RITE; the rest comes with transposition. Check it on the page for the EPBD.
The same platform provides the evidence for In-Use, for BREEAM Vivienda and for the EPBD, and it is already behind more than 5,000 homes rated at least BREEAM Very Good. A single point of contact for your projects.
BREEAM ES In-Use V6 requirements. BREEAM® is a registered trademark of BRE. Alfred Smart does not issue certifications.